Warrington Fire Global Safety - UK Building Regulations 2000

The Glasstex Wallcovering system can play an important role in fire safety by preventing spread of flames on the surface of most conventional building materials.

A range of various systems incorporating Glasstex products in conjunction with Beeline medium grade r / m adhesive have been tested in accordance with BS 476: Part 6 (Fire Propagation) and BS 476: Part 7 (Surface Spread of Flame) and the test results comply with the requirements for Class O rating as defined in paragraph A 13 (b) of Approved Document B (Fire Safety) to the Building Regulations 2000.

An overview of some of the systems tested together with the results obtained are detailed below.


FIRE TEST RESULTS
Test ReferenceBS 476: Part 7BS 476: Part 6
Surface Spread of FlameFire Propagation
Material ConstructionActual
flame spread
(mm)
Limit for
highest class
(mm)
Class
Result
(Highest 1)
Actual
Index
1.
Pass
Level
1.
Index
i 1
Pass
i 1
Building board
Primer
Adhesive
Glasstextile wallcovering
2 coats emulsion paint
Nil16511.012.00.76.0
Bulding board
Primer, 6 coats gloss
Adhesive
Glasstextile wallcoverings
2 coats emulsion paint
7516515.912.03.76.0
Plasterboard
Adhesive
Glasstextile wallcovering
1 coat emulsion
1 coat vinyl silk
5016517.812.04.36.0
Building board
Adhesive
Glasstextile wallcovering
1 coat emulsion
1 coat spray multicolour paint
Nil16513.012.01.56.0

The tests have been conducted by 'Warringtonfire' the UK's largest independent fire testing, research and certification organisation.

Copies of our test results are available on request on completion of projects from Eclipse Wallcoverings